Fig. 2

From: Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients

Fig. 2

Estimates of gait parameters with different amplitude settings. The three panels display changes in gait speed (A), stride length (B) and maximum sensor lift (C) in dependence of stimulation amplitude. In the X-axis, DBS parameters are displayed at 33, 66 and 100% of the original patient’s amplitude, respectively. Error bars show two standard errors of the estimated difference between each condition and the reference condition (OFF). The error for the reference condition itself is estimated from the average of all other errors. Significant differences with respect to the OFF condition are indicated with * (p < .05), ** (p < .01) and *** (p < .001) respectively